dLSP 510 |
dLSP 520 |
dLSP 510 Pro |
dLSP 520 Pro |
| Number of channels |
1 |
2 |
1 |
2 |
| Pusher advanve per microstep |
0.03255 μm/μstep |
0.015625 μm/μstep |
| Linear speed |
0.0833 µm/min - 180 mm/min |
0.04 µm/min - 86.4 mm/min |
| Step speed |
23.4375 sec/μstep - 10.85 μsec/μstep |
| Linear travel accuracy |
+/- 0.5% |
+/- 0.35% |
| Linear travel CV (Rated) |
+/- 0.05% |
| Linear force (Rated) |
40lbs/18kg@ 100% force selection |
| Motor and drive |
1.8° step motor with 1/64 microstepping |
| Syringe size |
0.5 µL - 60 mL |
0.5 µL - 30 mL |
0.5 µL - 60 mL |
0.5 µL - 30 mL |
| User-defined syringe |
Travel<108mm
OD<31.5mm |
Travel<108mm
OD<26mm |
Travel<108mm
OD<31.5mm
|
Travel<108mm
OD<26mm |
| Display |
7 inch, 1024x600, IPS HD LCD |
| Interface |
RS485(optional), USB-B, USB-A, Wifi, bluetooth, Ethernet, footswitch, 3 outputs- solid state relay signal, 2 inputs-switch signal or TTL signal, 4-20mA signal (optional) |
| Wireless connectivity (optional) |
Wifi, bluetooth |
| Programming function |
Parameter configured based on work flow: constant, ramp, loop, delay, repeat, I/O output trigger, I/O event input trigger, touch screen trigger |
| Calibration |
Improve flow rate/dispensing volume precision and accuracy |
| Paramether method |
Parameter methods can be stored and easily recalled |
| Clock |
Date and time can be set |
| Audible alarm |
For keypad clicks, end of run, near end of run, power on, motor stall, calibration reminder, etc. |
| Voice reminder |
N/A |
For working progress, alarm, diagnosis |
| Intelligent diagnosis |
N/A |
Presence of syringes
Syringe leakage |
| Screen lock |
To prevent misoperation |
| User access control |
Three levels of user accesses (administrator, developer, operator), in line with safety management requirement (21CFR Part 11) |
| Predictive maintenance |
Real-time monitoring of pump running status providing informaiton such as alarms, regular maintenance, predictive maintenance |
| Log record |
Record the complete operation history of the pump, and can be exported directly |
| Electronic signature and audit trail |
Meet the requirement of 21CFR Part 11
(on dedicated software) |
| Support 3Q(IQ/OQ/PQ) |
Meet GMP requirement |
| EMC |
CE (TUV) certified |
| Dimensions |
Drive unit: 260 mm x 15 mm x 180 mm
Controller: 190mm x 123 mm x 33 mm |
| Power supply |
AC 100V-240V/30W 50/60Hz |
AC 100V-240V/20W 50/60Hz |
| Operating condition |
Temperature 5-40 °C
Relative humidity <85% |
| IP rating |
IP31 |
| Weight |
Drive unit: 3.49 kg
Controller: 0.37 kg |
| Min. flow rate |
0.0007 nL/min (0.5 µL syringe)
|
0.0007 nL/min (0.5 µL syringe) |
0.0003 nL/min (0.5 µL syringe) |
0.0003 nL/min (0.5 µL syringe) |
| Max. flow rate |
120 mL/min (60 mL syringe) |
74.7 mL/min (30 mL syringe) |
57.6 mL/min (60 mL syringe) |
35.8 mL/min (30 mL syringe) |